For sensor installation, we recommend 0.5 square mm or less guage wire to be used like telephone cable. For power terminals, 2.5 Square mm wire to be used.
6 Nos Stainless Steel Different Colour Sensors. Option to bypass three underground tank sensors by looping C-UL-UH together if underground tank not available. All three sensors into water tank are must be installed for automatic operation.
Contact capacity : 30 A and Works Upto 2HP MCB type Starters & Direct two wires motor only
In Automatic Mode fully automatic operation based on sensors feedback. No need to press any start or stop buttons in automatic mode. In manual mode only, motor on off done by START STOP buttons.
Tank water level indications like UL(Underground Low-Red), UH(Underground High-Yellow), OL(Overhead Low-Yellow), OH(Overhead High-Red). Coulours of led's are used only for differentiation purpose. Motor on indication (Green).